无法使用静态IP打开远程工具? [英] Unable to open Remote tools with static IP??
问题描述
Hello Friends,
Hello Friends,
我在 中添加条目后配置了静态IP
I have configured Static IP after adding entries in cpsw3gMiniport.reg under
[HKEY_LOCAL_MACHINE\Comm\CPSW3G1\Parms\TcpIp]
"EnableDHCP"=dword:0
"DefaultGateway"="192.168.1.1"
"UseZeroBroadcast"=dword:0
"IpAddress"="192.168.1.98"
"Subnetmask"="255.255.255.0"
"DNS"="192.168.0.1"
当我从主机上ping Diable KITL时,我得到相同的IP ..
And I am getting same IP when I ping from host machinewith Diable KITL true..
但是当我打开像Reg Editor这样的Rermote工具时,由于无法打开,我收到错误。??????
But when I open the Rermote tools like Reg Editor, I got an error as unable to open.??????
因为,我也做了这里更改 -
As, I also made changes here -
cpgMacKitlMiniport.reg
cpgMacKitlMiniport.reg
[HKEY_LOCAL_MACHINE\Comm\CPSW3G1\Parms\TcpIp]
"EnableDHCP"=dword:1
"DefaultGateway"="192.168.1.1"
"UseZeroBroadcast"=dword:0
"IpAddress"="192.168.1.48"
"Subnetmask"="255.255.255.0"
"DNS"="192.168.1.1"
"Domain"=""
cpgMacMiniport.reg
cpgMacMiniport.reg
[HKEY_LOCAL_MACHINE\Comm\CPSW3G1\Parms\TcpIp]
"EnableDHCP"=dword:0
"DefaultGateway"="192.168.1.1"
"UseZeroBroadcast"=dword:0
"IpAddress"="192.168.1.99"
"Subnetmask"="255.255.255.0"
"DNS"="192.168.0.92"
"Domain"=""
我该怎么做才能使远程工具也可以使用静态IP ?????
What Should I do so that remote tools also work with static IP?????
推荐答案
您有一个设备和三个REG文件?坦率地说,这超出了我的视野。
You have one device and three REG files? Frankly, that's beyond my horizon.
你应该一步一步地做到这一点。远程工具utilite CoreCon,CoreCon利用TCP,TCP - > IP,IP->以太网,以太网 - >硬件。因此,当您插入电缆时,您应该验证您是否知道该设备的网络适配器具有IP
地址,您应该知道什么是IP地址。 一个简单的测试就是"ping"。命令。
You should make it step by step. Remote Tools utilite CoreCon, CoreCon utilizes TCP, TCP -> IP, IP->Ethernet, Ethernet->Hardware. So when you have plugged in the cable, you should verify that you know, that the device's network adapter has an IP address and you should know what IP address. A simple test is the "ping" command.
当ping给出有用的结果时,停止摆弄IP配置。
When ping gives useful result stop fiddling with IP configuration.
如果设备上有Telnet服务器,你可以连接设备并启动ConManclient3.exe和CMAccept3.exe。
If you have a Telnet server at the device you can connect the device and start ConManclient3.exe and CMAccept3.exe.
如果你有与Platform Builder的KITL连接,你可以在这里做同样的事情。
If you have a KITL connection to Platform Builder you can do the same here.
如果您没有连接启动进程,您必须确保ConManClient3.exe正在运行。一段时间后,CMAccept3.exe可能会停止。在最新的情况下,您应该考虑在注册表中设置CoreConOverrideSecurity。
If you have no connection to start a process you have to make sure that the ConManClient3.exe is running. CMAccept3.exe may stop after a while. In the latest case you should consider to set CoreConOverrideSecurity in your registry.
这篇关于无法使用静态IP打开远程工具?的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!