PPP和路由表 [英] PPP and routing table
问题描述
我正在尝试使用Windows 7与嵌入式设备建立PPP连接。我注意到在获得PPP连接后,我似乎遇到了其他以太网适配器的问题(我的Pidgin客户端失去了连接)。我没有在Windows XP上看到过这种行为
。
I am trying to establish a PPP connection to an embedded device using Windows 7. I have noticed that after I get a PPP connection, I seem to have a problem with other Ethernet adapters (my Pidgin client loses its connection). I have not seen this behavior on Windows XP.
这个问题可能与本文有关:http://stackoverflow.com/questions/7115887/clash-between- ppp-connections-on-windows-7
Could the problem be related to this article: http://stackoverflow.com/questions/7115887/clash-between-ppp-connections-on-windows-7
这是Windows 7上的已知问题吗?
Is this a known problem on Windows 7?
我有一台相当新的戴尔PC,有两块以太网卡,运行Windows 7 64位。
I have a fairly new Dell PC that has two Ethernet cards, running Windows 7 64-bit.
Frank
推荐答案
虽然这已经晚了一年,但我觉得没有答案令人沮丧。因此,鉴于我们必须解决这个问题,我将发布我们(我和我的同事)的解决方案。
Though this is a year late, I find it frustrating to see no answer. So given that we just had to solve this problem, I will post our (me and my colleagues) solution.
看来PPP连接正在破坏路由表。
It would appear that the PPP connection is trashing the routing table.
- 右键单击你的连接和选择属性。 (在控制面板,网络和Internet,网络连接下。)
- 选择网络选项卡。
- 选择"Internet协议版本4(TCP / IPv4)"
- 选择"属性"。
- 选择"高级"。
- 选中"禁用基于班级的路线添加。"
未经过此检查允许连接消除我们的其他路由。我怀疑这也是Frank的Pidgin客户端发生的事情。
Not having this checked allowed the connection to wipe out our other routes. I suspect that this what is happening to Frank's Pidgin client as well.
ETA:你可能还需要"在远程网络上使用默认网关"。
未选中 - 与上面的屏幕相同。
ETA: You may also need to have "Use default gateway on remote network" unchecked -- on the same screen as above.