IIS Express无法启动 [英] IIS Express will not start

查看:236
本文介绍了IIS Express无法启动的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

我只是要把它放在那里,因为它是Google零结果器,这意味着我赢了奖品?

I'm just putting this one out there since its a Google Zero-resulter which means I win a prize?

从一个帐户重新安装后无法启动IIS Express 7.5,但是以其他域帐户登录时可以.

Cannot start IIS Express 7.5 after reinstall from one account, but I can when logged-in under my other domain account.

奇怪的是,失败的帐户是我的具有本地管理员权限的超级"帐户,也是我在其下安装的帐户.

What's odd is that the account it fails under is my 'super' account with local admin rights, and is also the account I installed it under.

该错误源于diprestr.dll无法加载...

The error stems from diprestr.dll not loading...

C:\Program Files (x86)\IIS Express>iisexpress.exe /trace:error
Starting IIS Express ...
Initializing the W3 Server Started CTC = 2068729
W3 Server initializing WinSock.  CTC = 2068744
W3 Server WinSock initialized.  CTC = 2068744
W3 Server ThreadPool initialized (ipm has signalled).  CTC = 2068744
Failed to load global module C:\Program Files (x86)\IIS Express\diprestr.dll
Failed processing with hr = 8007007e
Error loading global modules.  hr = 8007007e
Terminating W3_SERVER object
Start listenerChannel http:0
Initializing the W3 Server Started CTC = 2069774
W3 Server initializing WinSock.  CTC = 2069774
W3 Server WinSock initialized.  CTC = 2069774
W3 Server ThreadPool initialized (ipm has signalled).  CTC = 2069774
Failed to load global module C:\Program Files (x86)\IIS Express\diprestr.dll
Failed processing with hr = 8007007e
Error loading global modules.  hr = 8007007e
Terminating W3_SERVER object
InitComplete event signalled
Report ListenerChannel stopped due to failure; ProtocolId:http, ListenerChannelId:0
Process Model Shutdown called
Failed to start 'HostedWASStart'.  Error = 38246848
HostableWebCore activation failed.
Unable to start iisexpress.

The specified module could not be found.
For more information about the error, run iisexpress.exe with the tracing switch enabled (/trace:error).

有什么想法吗?我将尝试使用Process Monitor来查看.

Any got any ideas? I'll try Process Monitor and see.

到目前为止,事实证明,IIS Express只是学习和出错的另一回事.

So far, IIS Express is proving to be just another thing to learn and go wrong.

推荐答案

检查失败的用户的主文件夹中是否有IISExpress\config文件夹.如果不是,则从运行IISExpress的用户那里复制它.当缺少配置文件/文件夹时,这是常见故障.

Check that the user its failing has a IISExpress\config folder in their home folder. If not then copy it over from the user where IISExpress is working. This is a common fault when the config files/folders are missing.

这篇关于IIS Express无法启动的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!

查看全文
登录 关闭
扫码关注1秒登录
发送“验证码”获取 | 15天全站免登陆