在BizTalk接收位置中的自定义管道组件之后,映射不会执行。 [英] Map does not execute after Custom Pipeline component in BizTalk Receive location.

查看:68
本文介绍了在BizTalk接收位置中的自定义管道组件之后,映射不会执行。的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述


我有一个自定义管道组件。当我们在接收端口处在接收端口处应用具有此管道组件的映射时,映射不会被执行。


如果我们创建一个发送端口并根据消息进行订阅输入和应用相同的地图作为出站地图,它可以工作。


问题:我们需要在接收端口应用地图。可能是地图不执行的原因。




问候,


Sharmishtha

解决方案

由于自定义管道组件,消息类型是否被搞砸/未正确升级?您在自定义管道组件中做了什么?它的使用阶段是什么阶段?


可以在这里找到有关如何在港口解析地图的详细信息 -


https://srirambiztalks.wordpress.com/2011/02/ 10 / inboundoutbound-maps-with-same-messagetype-order-of-execution /


您可以尝试一件事:取消订阅订阅ReceivePort的SendPort使用自定义管道组件,以便入站邮件被挂起。现在,从管理控制台检查已挂起邮件的邮件上下文属性等。


编辑:同时检查您是否遇到此处描述的这种情况(这是导致自定义管道组件混淆的常见原因) -


https://social.technet.microsoft.com/Forums/scriptcenter/en-US/bc9fc6dd-8f10-466e-b7cc-83ea32c14bc5/xml-diassembler-component-is-not-doing- property-promotion?forum = biztalkgeneral




Hi,

I have a custom pipeline component. When we apply a map at the receive port that has this pipeline component at the Receive location, the map does not get executed.

If we create a send port and subscribe on the basis of message Type and apply the same map as an outbound map, it works.

Problem : we need to apply the map at the receive port. what can be the reason for the map not to execute.

Regards,

Sharmishtha

解决方案

Is the messagetype getting messed up/not being promoted correctly due to the custom pipeline component?What are you doing in the custom pipeline component? What stage of the pipeline is it being used?

Details of how a map is resolved at a port can be found here-

https://srirambiztalks.wordpress.com/2011/02/10/inboundoutbound-maps-with-same-messagetype-order-of-execution/

One thing you can try : Un-enlist the SendPort that is subscribing to your ReceivePort with the custom pipeline component, so that the inbound message gets suspended. Now check from Admin console the message context properties, etc. on the suspended message.

Edit: Also check if you running into this scenario described here(which is a common cause of confusion for custom pipeline components)-

https://social.technet.microsoft.com/Forums/scriptcenter/en-US/bc9fc6dd-8f10-466e-b7cc-83ea32c14bc5/xml-diassembler-component-is-not-doing-property-promotion?forum=biztalkgeneral


这篇关于在BizTalk接收位置中的自定义管道组件之后,映射不会执行。的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!