GCP负载平衡器502服务器错误和"backend_connection_closed_before_data_sent_to_client"和"IIS 10 [英] GCP load balancer 502 server error and "backend_connection_closed_before_data_sent_to_client" IIS 10

查看:336
本文介绍了GCP负载平衡器502服务器错误和"backend_connection_closed_before_data_sent_to_client"和"IIS 10的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

我有带有4个IIS 10 Web服务器的GCP负载平衡器.偶尔会出现 502-服务器错误.在日志中显示它是由于 backend_connection_closed_before_data_sent_to_client 引起的.我已阅读文章 https://cloud.google.com/compute /docs/load-balancing/http/,它表示nginx和apache的keepalive timout需要设置为620秒.如何在IIS 10中执行相同的操作.

I have GCP load balancer with 4 IIS 10 web servers. Sporadically it comes with 502-Server error. In the logs it shows it is because of backend_connection_closed_before_data_sent_to_client. I have read thru the article https://cloud.google.com/compute/docs/load-balancing/http/ and it says keepalive timout need to be set to 620 seconds for nginx and apache. How do I do the same in IIS 10.

推荐答案

在筹集到票务后,谷歌云团队解决了这个问题.我把它放在这里,以便其他人可以从中受益.

Figured this out after raising a ticket google cloud team. I am putting it here so that others can benefit.

步骤1:在Google Cloud Load Balancer中设置超时

Google云负载均衡器中有两个超时设置.

There are two timeout settings in Google cloud load balancer.

  1. 超时
  2. 连接耗尽超时.
  1. Timeout and
  2. Connection draining timeout.

请参见下面的屏幕截图.

See the screenshot below.

以上两个设置都必须相同.在我们的例子中,有许多长时间运行的请求,并且将其设置为1800秒.

Both the above settings need to be the same. In our case, there are a number of long running requests and it is set to 1800 seconds.

步骤2:在IIS中将连接超时设置为比负载平衡器设置大20秒

在IIS站点名称下-转到高级设置,然后将连接超时值设置为比负载均衡器超时多20秒.以我的情况为1820.

Under IIS Site name - go to Advanced settings and then set the Connection Time-out value to 20 seconds more than the load balancer timeout. In my case 1820.

这个想法是IIS连接在负载均衡器之前不应该超时.如果超时,则可能导致 backend_connection_closed_before_data_sent_to_client 错误.

The idea is that the IIS connection should not timeout before load balancer. If it times out then it may leads to backend_connection_closed_before_data_sent_to_client error.

这篇关于GCP负载平衡器502服务器错误和"backend_connection_closed_before_data_sent_to_client"和"IIS 10的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!

查看全文
登录 关闭
扫码关注1秒登录
发送“验证码”获取 | 15天全站免登陆