C#数据读取器值在调试时重复多次 [英] C# data reader value repeats multiple times while debugging

查看:103
本文介绍了C#数据读取器值在调试时重复多次的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

我正在从SQL Server表中读取数据,并将相同的值插入PostgreSQL数据库表中。这是一个数据迁移过程。

I am reading data from SQL server table and inserting the same value in the PostgreSQL database table. It's a data migration process.

问题是SQL中的数据是纯文本,但是我在调​​试中看到它,它在watch中多次显示相同的值(可视studio 2015)。

The issue is that the data in the SQL is plain text but I see it in the debugging it shows same value multiple times in watch (visual studio 2015).

值在SQL Server中显示如下:

Value displays in SQL server as below:

数据在Visual Studio调试器中显示:

Data shows in the visual studio debugger:

所有迁移过程都可以正常工作,但是唯一具有这些类型的值的表不会插入PostgreSQL中,并且会引发异常。

All migration process works fine but the only table having these type of value does not insert in the PostgreSQL and will throw an exception.

例外:

{"22021: invalid byte sequence for encoding \"UTF8\": 0x00"}

Stacktrace:

Stacktrace:

我无法理解确切的问题。能否请您帮助我理解上述问题的原因和解决方法。

I cannot understand the exact issue. Can you please help me understand the cause and solution of the above issue.

推荐答案

我怀疑显示的内容 SQL Server中的值仅在Unicode代码点0(U + 0000)处停止,这是Windows控件默认执行的操作。看来Postgres根本不接受。

I suspect what whatever's displaying the value in SQL Server is just stopping at Unicode code point 0 (U+0000), which is what Windows controls do by default. It looks like Postgres simply doesn't accept that.

我相信您应该:


  • 尝试弄清楚为什么要在SQL Server中获得像这样的价值。 (在执行插入操作的任何代码中都可能是一个错误。)

  • 确定要想要的数据。如果您实际上需要U + 0000之后的数据,则需要确定这是否意味着更多的行,不同的分隔符等。

  • Ether SQL Server中的数据(例如,通过在每个字段的U + 0000之前截断)或执行截断作为迁移的一部分(取决于您进行迁移的方式)。

  • Try to work out why you've got the value like that in SQL Server to start with. (It could well be a bug in whatever code is doing the insert.)
  • Determine what you want the data to be. If you actually need the data after U+0000, you'll need to work out whether that means more rows, a different separator etc.
  • Either fix the data in SQL Server (e.g. by truncating before the U+0000 in every field) or perform the truncation as part of the migration (depending on how you're doing the migration).

这篇关于C#数据读取器值在调试时重复多次的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!