"fiware-servicepath"标头值与通知的上下文响应数不匹配 [英] 'fiware-servicepath' header value does not match the number of notified context responses

查看:75
本文介绍了"fiware-servicepath"标头值与通知的上下文响应数不匹配的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

正在将Cygnus设置为CKAN的接收器,但出现此错误,Cygnus设置的哪一部分负责此(订阅,配置...)

Working on setting Cygnus as a sink to CKAN, and I get this error, what part of Cygnus setup is responsible for this( subscription, configuration ...)

cygnus_1  | time=2018-10-01T12:40:04.517Z | lvl=DEBUG | corr=1ea858dc-c577- 
11e8-b0fd-0242ac140003 | trans=5c553916-f5e6-4bbc-b98a-bcaba61a306c | 
srv=waste4think | subsrv=/room/test | comp=cygnus-ngsi | op=getEvents | 
msg=com.telefonica.iot.cygnus.handlers.NGSIRestHandler[320] : 
[NGSIRestHandler] Parsed NotifyContextRequest:{" 
subscriptionId":"5bb2153fd1bde90f8813b236","originator":"null","contextResponse    
s":[]}

我认为该错误与该contextResponses有关,因为它为空,但是我没有发现任何其他信息导致此情况出现在我应该看的地方.而且错误没有帮助.

I assume the error is connected to this contextResponses because it is empty, but I found no additional info what is causing this where I should look. And the error is not helping.

这是一个更普遍的问题,因为我无法称呼这个问题,因为我不知道是由我造成的,还是天鹅座的确有一些问题.

This is the more general question that issue since I cannot call this issue because I have no idea if it is me who is causing this or Cygnus to have indeed some problems.

谢谢.

推荐答案

设置订阅时,天鹅座当前仅接受旧版NGSI v1格式的通知-因此需要attrsFormat=legacy.

When setting up the subscription, Cygnus currently only accepts notifications in the older NGSI v1 format- the attrsFormat=legacy is therefore needed.

例如

curl -iX POST \
  'http://localhost:1026/v2/subscriptions' \
  -H 'Content-Type: application/json' \
  -H 'fiware-service: openiot' \
  -H 'fiware-servicepath: /' \
  -d '{
  "description": "Notify Cygnus of all context changes",
  "subject": {
    "entities": [
      {
        "idPattern": ".*"
      }
    ]
  },
  "notification": {
    "http": {
      "url": "http://cygnus:5050/notify"
    },
    "attrsFormat": "legacy"
  },
  "throttling": 5
}'

有关在Cygnus中设置订阅的其他信息,可以在

Further information about setting up subscriptions in Cygnus can be found in the Cygnus Tutorial

这篇关于"fiware-servicepath"标头值与通知的上下文响应数不匹配的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!