如何安全地将Hangfire重置为干净状态? [英] How can I safely reset Hangfire to a clean state?

查看:479
本文介绍了如何安全地将Hangfire重置为干净状态?的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

我有一台装有Hangfire的服务器.我已经有一段时间没有检查过了,看来一项经常性工作已经变得很无赖.它停止工作,然后重试堆积,看起来似乎完全锁住了.

I have a server with Hangfire installed. I haven't checked it for a while and it seems one recurring job has gone rogue. It stopped working and then it has stacked up with retries resulting in a complete lock it seems.

我想清除数据库并重新开始.我可以只删除所有表中的数据,还是应该删除表并让Hangfire为我重新创建它们?我这样做会冒险吗?

I would like to clear my database and start over. Can i just delete the data from all tables or should I drop the tables and let Hangfire recreate them for me? Am I risking anything by doing this?

Hangfire.State使用整个Azure Basic数据库2GB的空间.

Hangfire.State using entire Azure Basic database 2GB of space.

推荐答案

我最终删除了表,起初查询根本不起作用,只是继续进行而没有任何反应.然后,我使用了TRUNCATE TABLE [HangFire].[State],此后一切都像灵符一样工作.这是我用于Hangfire 1.5.6UseSqlServerStorage的脚本:

I ended up dropping the tables, at first the query did not work at all, it just kept going and nothing happened. I then used TRUNCATE TABLE [HangFire].[State] and it all worked like a charm after. Here is the script I used for Hangfire 1.5.6 with UseSqlServerStorage:

GO
PRINT N'Dropping [HangFire].[FK_HangFire_State_Job]...';


GO
ALTER TABLE [HangFire].[State] DROP CONSTRAINT [FK_HangFire_State_Job];


GO
PRINT N'Dropping [HangFire].[FK_HangFire_JobParameter_Job]...';


GO
ALTER TABLE [HangFire].[JobParameter] DROP CONSTRAINT [FK_HangFire_JobParameter_Job];


GO
PRINT N'Dropping [HangFire].[Schema]...';


GO
DROP TABLE [HangFire].[Schema];


GO
PRINT N'Dropping [HangFire].[Job]...';


GO
DROP TABLE [HangFire].[Job];


GO
PRINT N'Dropping [HangFire].[State]...';


GO
DROP TABLE [HangFire].[State];


GO
PRINT N'Dropping [HangFire].[JobParameter]...';


GO
DROP TABLE [HangFire].[JobParameter];


GO
PRINT N'Dropping [HangFire].[JobQueue]...';


GO
DROP TABLE [HangFire].[JobQueue];


GO
PRINT N'Dropping [HangFire].[Server]...';


GO
DROP TABLE [HangFire].[Server];


GO
PRINT N'Dropping [HangFire].[List]...';


GO
DROP TABLE [HangFire].[List];


GO
PRINT N'Dropping [HangFire].[Set]...';


GO
DROP TABLE [HangFire].[Set];


GO
PRINT N'Dropping [HangFire].[Counter]...';


GO
DROP TABLE [HangFire].[Counter];


GO
PRINT N'Dropping [HangFire].[Hash]...';


GO
DROP TABLE [HangFire].[Hash];


GO
PRINT N'Dropping [HangFire].[AggregatedCounter]...';


GO
DROP TABLE [HangFire].[AggregatedCounter];


GO
PRINT N'Dropping [HangFire]...';


GO
DROP SCHEMA [HangFire];


GO
PRINT N'Update complete.';


GO

这篇关于如何安全地将Hangfire重置为干净状态?的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!