CU2之后的BizTalk 2013R2的加载类型发生故障 [英] Failure has occurred loading type after CU2 for BizTalk 2013R2
问题描述
在BizTalk 2013R2中安装CU2后,出现以下错误
After installing CU2 in BizTalk 2013R2 we got the following error
加载类型失败
Failure has occurred loading type
看起来好像发生在港口的地图上
It looks like it is occurring in the map on the port
推荐答案
There is an explanation of the issue in this blog BizTalk 2013 R2 CU2 – Failure has occurred while loading a type where apparently they have introduced a new Use XSLT transform attribute in the map, grid properties under Standalone. Setting this attribute and redeploying fixes it, but that may be too much risk for a Production environment,
它已由Microsoft提出,希望能作为修补程序发布.
It has been raised with Microsoft, and hopefully will get released as a hot fix.
就目前而言,如果您可以不用CU2,那么我将推迟应用CU2,直到它得到修复或此修复程序可用为止.
For now, if you can do without CU2 I would hold off on applying CU2 until it is fixed or the hotfix is available.
更新:Microsoft发布了新的CU2-程序包,其中包含针对该问题的修补程序.您可以从 https://support.microsoft.com/en-us/kb/下载3119352
UPDATE: Microsoft released a new CU2-package with a hotfix for the problem. You can download it at https://support.microsoft.com/en-us/kb/3119352
这篇关于CU2之后的BizTalk 2013R2的加载类型发生故障的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!