安装 RedMon 后无法在 Windows 7 中添加新的重定向端口 [英] Can't add new Redirected Port in Windows 7 after installing RedMon

查看:39
本文介绍了安装 RedMon 后无法在 Windows 7 中添加新的重定向端口的处理方法,对大家解决问题具有一定的参考价值,需要的朋友们下面随着小编来一起学习吧!

问题描述

我的操作系统是 Windows 7 32 位.我安装了 RedMon1.7Ghostscript 8.71GSview 4.9;安装成功.我在 Windows Devices and Printers 中的 Add New Local Printer,点击 Create A New Port,然后选择 Redirected Portstrong> 来自 端口类型 列表.单击下一步,在 添加新端口 窗口中,我命名为 RPT1:并单击确定,但它显示 无法添加指定端口.操作无法完成(错误0x00000001)

My operating system is Windows 7 32bit. I installed RedMon1.7, Ghostscript 8.71 and GSview 4.9; installations were successful. I went to Add New Local Printer in Windows Devices and Printers, clicked on Create A New Port, and selected Redirected Port from the Type of Port list. Clicked Next and in the Add New Port window I named RPT1: and clicked OK but it says Specified port cannot be added. Operation could not be completed (error 0x00000001)

我尝试为端口指定不同的名称,RPT2:、RPT4:、VPport: 等,但都给出了相同的结果.禁用了 Windows 防火墙并尝试了,但它继续给出相同的错误,禁用了防病毒 (Avira) 但没有任何变化.

I tried giving different names to the port, RPT2:, RPT4:, VPport: etc but all gave same result. Disabled Windows Firewall and tried but it continues to give same error, Disabled the Antivirus (Avira) but no change.

什么可以阻止 Windows 7 添加重定向端口?

What can be preventing windows 7 from adding redirected port?

顺便说一句,我按照本教程中的说明来创建 postscript 打印机.

BTW I was following instructions in this tutorial in order to create a postscript printer.

http://www.stat.tamu.edu/~henrik/GSPSprinter/GSPSprinter.html

欣赏任何想法或建议.谢谢

Appreciate any ideas or suggestions. Thanks

推荐答案

以管理员身份运行cmd.exe,然后运行:

Run cmd.exe as Administrator and then run:

rundll32 printui.dll,PrintUIEntry /il

来自提升的 cmd.

这篇关于安装 RedMon 后无法在 Windows 7 中添加新的重定向端口的文章就介绍到这了,希望我们推荐的答案对大家有所帮助,也希望大家多多支持IT屋!